SD-2 Generator Interlock Kit

this kit fits brands:

Square D

type of circuit breaker panel:

1 handle horizontal throw left to right main breaker centered over 2 breaker columns with a 1 3/8" space between main breaker and column breakers

panel spaces used:

2 at the top of the right side breaker column

SD-2 Generator Interlock Kit - (price includes 2-3 day USPS Shipping)
$69.00 Add to Cart
If using a QO circuit breaker for the generator, use the SD-2QO model interlock

SD-2QO Generator Interlock Kit - (price includes 2-3 day USPS Shipping)
$69.00 Add to Cart
National Electrical Code requires a system in place that prevents an emergency generator feeding back into the utility line. This interlock will only allow the generator breaker to be switched on if the main breaker is off. Or the main breaker to be turned on if the generator breaker is off.

You will also need:
  • A generator with a 240 volt outlet
  • A double breaker located at the top of the right side breaker column of your electrical panel box
  • An inlet box and wiring connected to that double breaker
Using this interlock will allow you to power your existing house wiring with your generator (within its wattage limits), including 220v circuits such as a well pump.